IMPORTANT
INFORMATION AND FORMULAS FOR CIVIL ENGINEERS
Steel = 7850kg/Cum
Cement=1440kg/cum
brick=1682kg/cum or 1920kg/cum
sand=1100to 1600kg/cum
WATER-1000kg/cum
R.C.C-2500kg/cum (5% STEEL)
P.C.C-2400kg/cum
WOOD-1100kg/cum
CRUSHED BRICK-950-1250kg/cum
Cement=1440kg/cum
brick=1682kg/cum or 1920kg/cum
sand=1100to 1600kg/cum
WATER-1000kg/cum
R.C.C-2500kg/cum (5% STEEL)
P.C.C-2400kg/cum
WOOD-1100kg/cum
CRUSHED BRICK-950-1250kg/cum
IMPORTANT
POINTS TO REMEMBER
1.
Minimum thickness of slab is 125 mm.
2.
Water absorption should not be more than 15 %.
3.
Dimension tolerance for cubes + – 2 mm.
4.
Lapping is not allowed for the bars having diameters more than
36 mm.
5.
Chair spacing maximum spacing is 1.00 m (or) 1 No per 1m2.
6.
For dowels rod minimum of 12 mm diameter should be used.
7.
Chairs minimum of 12 mm diameter bars to be used.
8.
Longitudinal reinforcement not less than 0.8% and more than 6%
of gross C/S.
9.
Minimum bars for square column is 4 No’s and 6 No’s for circular
column.
10.
Main bars in the slabs shall not be less than 8 mm (HYSD) or 10
mm (Plain bars) and the distributors not less than 8 mm and not more than 1/8
of slab thickness.
11.
Minimum thickness of slab is 125 mm.
12.
Dimension tolerance for cubes + 2 mm.
13.
Free fall of concrete is allowed maximum to 1.50m.
14.
Lap slices not be used for bar larger than 36 mm.
15.
Water absorption of bricks should not be more than 15 %.
16.
PH value of the water should not be less than 6.
17.
Compressive strength of Bricks is 3.5 N / mm
18.
In steel reinforcement binding wire required is 8 kg per MT.
19.
In soil filling as per IS code, 3 samples should be taken for
core cutting test for every 100m2.
20.
Compressive strength of Bricks is 3.5 N /mm2 .
FEW MORE
1.
Maximum Free fall of concrete allowed is 1.50 m.
2.
In soil filling as per IS code for every 100 sq m 3 sample for
core cutting test should be taken.
3.
Electrical conduits shall not run in column.
4.
Earth work excavation for basement above 3 m should be stepped
form.
5.
Any back filling shall be compacted 95% of dry density at the
optimum moisture content and in layers not more than 200 mm for filling above
structure and 300 mm for no structure.
6.
F soling is specified the soling stones shall be laid at 45° to
60° inclination (and not vertical) with interstices filled with sand.
7.
A set of cube tests shall be carried out for each 30 cum of
concrete / each levels of casting / each batch of cement.
8.
Water cement ratio for different grades of concrete shall not
exceed 0.45 for M20 and above and 0.50 For M10 / M15.
9.
For concrete grades M20 and above approved admixture shall be
used as per mix design requirements.
10.
Cement shall be stored in dry places on a raised platform about
200mm above floor level and 300mm away from walls. Bags to be stacked not more
than 10 bags high in such a manner that it is adequately protected from
moisture and contamination.
11.
Samples from fresh concrete shall be taken and at least a set of
6 cubes of 150mm shall be prepared and cured. 3 Cubes each at 7 days and 28
days shall be tested for compressive strength. The test results should be
submitted to engineer for approval. If results are unsatisfactory necessary
action/rectification/remedial measures has to be exercised.
12.
Water used for both mixing and curing shall be clean and free
from injurious amounts of oils, acids, alkali, salts, sugar and organic
materials or other substances that may be deleterious to concrete or steel. The
PH. shall be generally between 6 and 8.
Comments